Minimum verification interval: Vmin = EMax / 10.000;
Maximum number of load cell divisions: nLC=3000 (C3);
Full Scale Output: 2mV/V +/- 0,2%;
Temperature effect on full scale output: 0,0014%FS/°C;
Tempeature effect on the zero: +/- 0,0017%FS/°C;
Compensated temperature range: -10°C/+40°C;
Operating temperature range: -35°C/+65°C;
Creep error after 30 minutes: 0,02% F.S;
Excitation voltage: from 5 to 18 VDC;
Input Resistance: 750 Ohm;
Output Resistance: 700 ± 7 Ohm;
Zero Balance: +/-1,5% F.S.;
Insulation resistance > 5000 MOhm;
Safe overload > 150% F.S.;
Maximum overload 300% F.S.;
4-wire shielded cable, 15m long, 6mm diameter.
The CCATEX certificate makes the load cell suitable for use in hazardous areas with protection methods according to:
The certificate includes the manual and the ATEX CE conformity declaration (available in EN, DE, FR, and IT).
IMPORTANT: the certificate refers to the single load cell. For systems with more load cells, it is necessary to order one certificate for each load cell.
| Class | C3 |
|---|---|
| Max (kg) | 30t |
| ATEX Option | Optional |
| Cable Length | 15m |
| IP Rating | IP68 |