Maximum number of verification intervals: nLC = 3000
Full Scale Output: 2mV/V +/- 10%
Temperature effect on zero: from ±0,0093% F.S./10K to ±0,0175% F.S/10K
Temperature effect on full scale output: 0,0117% F.S./10K (-10°C/+20°C) 0,0175% F.S./10K (+20°C/+40°C)
Compensated Temperature Range: -10°C/+40°C
Operating Temperature Range: -10°C/+50°C
Maximum tolerated excitation voltage: 15 VDC
Input Resistance: 300..500 Ohm
Output Resistance: 300..500 Ohm
Insulation Resistance: >2000 MOhm
Safe Overload: 150% F.S.
Ultimate Overload: 300% F.S.
4-wire shielded cable, 40cm long, 3,2mm diameter
ATEX Version:
The CCATEX certificate makes the load cell suitable for use in hazardous areas with protection methods according to:
ATEX II 1G Ex ia IIC T6 (Ta -20÷+40°C) TX (Ta -20÷+65°C) Ga
ATEX II 1D Ex ta IIIC TX°C (Ta -20÷+40°C) TX°C (Ta -20÷+65°C) Da IP65.
The certificate includes the manual and the ATEX CE conformity declaration (available in EN, DE, FR, and IT).
IMPORTANT: the certificate refers to the single load cell. For systems with more load cells, it is necessary to order one certificate for each load cell.